柯达8100、8200干式相机部分关键错误代码
 

   目前干机的市场占有率越来越高,8100/8200以其高性价比成为kodak产品中的佼佼者。该机器的故障率还是比较高的。贴部分错误位置及代码与广大同行共勉。
有什么需要帮助的,请联系。
QQ:404748515。EMAIL:sansu100@yahoo.com.cn

LOCAL PANEL Status Messages(面板状态信息)
Status Code Message Explanation(状态代码信息描述)

S00 Self Test The IMAGER is performing its start-up self test. Please wait.(自检)

S01 Ready The IMAGER is idle and available for acquiring and printing(准备)
images.

S02 Warming The IMAGER is warming up. Please wait for Ready message.
( the number of minutes until the IMAGER will be ready to
operate.)(预热)

S04 Stopped An error condition has caused the IMAGER to stop. Refer to
the error message on line 2 of the display.(停止)

S11 Printing The IMAGER is printing an image.(正在打印)

S12 Calibrate The IMAGER is printing a calibration print.(校正)

S13 Contrast The IMAGER is printing a contrast test print.(打印对比度测试片)

S14 Density The IMAGER is printing a density test print.(打印密度测试片)

S16 Wait 1. The IMAGER is completing films in process before
unlatching the FRONT DOOR, or
2. There is an error condition. Refer to line 2 of the display.(等待)

S21 Door Open The FRONT DOOR is open.(前门开)

S22 Hood Open The UPPER HOOD is open.(上盖开)

S23 Doors Open Both the FRONT DOOR and UPPER HOOD are open.(前门和上盖一起开)

S24 Crtg Openg The IMAGER is opening the FILM CARTRIDGE.(打开片盒)

S25 Crtg Clsng The IMAGER is closing the FILM CARTRIDGE.(关闭片盒)

P602,可以不换激光头,调MCS板的relay k2。看MCS log.ok